Vehicle Barriers
Frontline Automation supplies and installs a comprehensive range of vehicle control barrier systems that are designed for maximum practicality and trouble-free use.
The FA6000 Automatic Raise Arm Barriers are designed to offer long-term reliability, efficient operation and durability. They incorporate an integral 3-phase inverter driven motor and gearbox drive, which only requires a single-phase supply, providing a smooth consistent operation.
All our FA6000 are CE Approved (Conforms to BS6571)
All of our barriers work with a range of access control.Full ranges of our access control can be found on our "Access Control" Page.
Once the barrier is opened it will remain open for a preset time (variable between 0-120 seconds) and then automatically close provided that all safety photoelectric beam(s) and/or safety vehicle loop(s) are clear. In the event of power failure the barrier(s) drive system has a manual hand wind, which can be used to raise and lower the barrier.
FA6000B
The FA6000B Barrier is ideal for settings where a small 100% duty cycle barrier is needed. It is the smallest in our range but like all our products built to last.
Specification:
| Maximum Boom Length: | 4.0 Meters |
| Boom Diameter: | 76mm |
| Opening/Closing Time: | 1.2 - 4.0 Seconds |
| Drive Unit: | 3-Phase Motor & Wormed Gearbox |
| Power Supply: | Single-Phase 230V, 50Hz, 5Amps |
| Finish: | Zinc Plated & Polyester Powder Coated |
| Cycles: | 100% Continuous Duty Rating |
| Dimensions: | 325mm x 255mm x 1020mm (Centre of Pivot) |
FA6000HD
The FA6000HD Barrier is ideal for settings where road width is up to 9 meters wide. It can accommodate a bottom skirt up to 8.5 meters and hi-bar skirt up to 6.5 meters.
Specification:
| Maximum Boom Length: | 9.0 Meters |
| Boom Diameter: | 100mm |
| Opening/Closing Time: | 4.0 – 10.0 Seconds |
| Drive Unit: | 3-Phase Motor & Wormed Gearbox |
| Power Supply: | Single-Phase 230V, 50Hz, 5Amps |
| Finish: | Zinc Plated & Polyester Powder Coated |
| Cycles: | 100% Continuous Duty Rating |
| Dimensions: | 506mm x 506mm x 1020mm (Centre Of Pivot) |
FA6000LUX
The FA6000LUX Barrier is ideal for settings where Heavy Duty variant is too much, but accessories such as LED lights and skirting are needed up to 7 meter spans.
Specification:
| Maximum Boom Length: | 7.0 Meters |
| Boom Diameter: | 76mm |
| Opening/Closing Time: | 2.0 – 7.0 Seconds |
| Drive Unit: | 3-Phase Motor & Wormed Gearbox |
| Power Supply: | Single-Phase 230V, 50Hz, 5Amps |
| Finish: | Zinc Plated & Polyester Powder Coated |
| Cycles: | 100% Continuous Duty Rating |
| Dimensions: | 360mm x 405mm x 1020mm (Centre Of Pivot) |
FA6000S
The FA6000S Barrier is ideal for settings where a Heavy Duty variant is too much, but accessories such as LED lights and skirting are needed up to 6 meter span.
Specification:
| Maximum Boom Length: | 6.0 Meters |
| Boom Diameter: | 76mm |
| Opening/Closing Time: | 2.0 – 6.0 Seconds |
| Drive Unit: | 3-Phase Motor & Wormed Gearbox |
| Power Supply: | Single-Phase 230V, 50Hz, 5Amps |
| Finish: | Zinc Plated & Polyester Powder Coated |
| Cycles: | 100% Continuous Duty Rating |
| Dimensions: | 350mm x 330mm x 1020mm (Centre Of Pivot) |
Safety Controls & Maintenance
BS-EN13241-1 is the safety standard for installation, testing and ongoing compliance of automatic gate, door and vehicle barrier systems. The standard has been in force in the UK since February 2008 and ALL new gate systems installed should comply with the standard. In short, the standard is designed to protect you, the end user, from risks associated with entrapment between parts of a moving swing or sliding gate. The standard covers both commercial and residential systems and stipulates the following
1. A swing (hinged) or sliding gate, when colliding with an obstruction, must exert a force of less than 400N before the drive unit stops due to detection of an obstacle.
2. The gate must then reverse to safely clear the obstruction within 0.75 seconds.
3. The entire leading edge of a swing or sliding gate, up to a height of 2.5m, must be fitted with an active obstacle detection system.
4. The obstacle detection system must be tested and accredited to another standard, BS-EN1760-2 that governs quality, durability and failure monitoring, to ensure that the gate will not function unless the safety system is in good working order.
Fitment of safety equipment, and maintenance of, is an integral part of all automated systems and are essential in order to comply with the following regulations:
| BS EN 12978 | Safety devices, requirements and test methods |
| BS EN 13241-1 | Safety and performance requirements |
| BS EN 12445 | Safety in use of power operated doors. Test methods |
| BS EN 12453 | Safety in use of power operated doors. Requirements |
The Machine Directive 98/37/EC as amended by Directive 98/79/EC